Chemical

Page 2 of 2

Description:

Hazard:
Conatiners of solvent (acetone) not properly labeled or covered.

Description:

Hazard:
Containers of solvent and glue not properly labeled.

Description:

Hazard:
Employees not trained in lead hazard.

Standard:

1910.106(e)(2)(iv) and 1200(f)

Standard:

1910.1200(f)

Standard:

1910.1025(l)

Abatement:

Containers were properly labeled as per MSDS and provided covers.

Abatement:

Containers were properly labeled as per MSDS.

Abatement:

Lead training added to the employer's soldering certification program.

 

 

 

 

 

 

Description:

Hazard::
Spray area not constructed of steel, or of concrete or masonry or aluminum. Spray area was constructed of wood and plastic was lining the walls inside.

Description:

Exposure to airborne lead

Description:

Hazard:
Unlabelled container

Standard:

1910.107

Standard:

No violation observed, just good PPE.

Standard:

1910.1200(f)(5)(i)

Abatement:

Construct the spray area of steel or concrete, masonry or aluminum.

 

 

 

Abatement:

Properly label chemical container