Description:
|
Acceptable rebar cap.
|
Description:
|
Hazard: Doubled lanyards - Personal fall arrest system rigged such that employee could free fall more than 6'. Lanyard length extended by connecting two six foot lanyards.
|
Description:
|
Hazard: The stairrail system along the unprotected sides of the first flight of the stairway do not have midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members between the top rail of the stairrail system and the stairway step.
|
|
Standard:
|
1926.701
|
Standard:
|
1926.502(d)(16)(iii)
|
Standard:
|
29 CFR 1926.1052 ( c) (4)
|
|
|
|
Abatement:
|
Lanyard length should be limited to six foot.
|
Abatement:
|
Install a mid-rail, mesh, or other acceptable component.
|
|
|
|
|
|
|
|
|
|
|
|
|
Description:
|
Employees are exposed to a fall hazard greater than 6 feet, while working on the ledge of masonry block wall without fall protection. Employees are working adjacent to unprotected protruding reinforcing steel (rebar) which creates an impalement hazard.
Employees are sitting on the scaffold working level without any fall protection, exposing themselves to a fall of over 10 feet.
|
Description:
|
Employees performing roofing work on a residential construction (home) is exposed to fall hazard. employee is carrying felt to complete the roof installation at a height over 6 feet.
|
Description:
|
Hazard: Employees working above 4-feet on machine platform with protection.
|
|
Standard:
|
1926.501(b)(1); 1926.701(b) 1926.451(g)(1), 1926.451(e)(1)
|
Standard:
|
1926.501(b)(10)(11)(13), 1925.503(a)(1)
|
Standard:
|
1910.23(c)(1)
|
|
Abatement:
|
Provide a fall protection system or work platform meeting the requirements of OSHA standards. Reference 1926.502. Provide adequate covers over reinforcing steel.
Provide standard guardrail system consisting of a top rail, midrail and toeboard as required. The employer needs to verify that the scaffold frame side rails are manufactured for employees to access the various working heights.
|
Abatement:
|
Employer needs to evaluate the height to determine minimum fall requirements and necessary training. Reference - STD 3.1. for falls less than 25 feet and require conventional fall protection for falls greater than 25 feet.
|
Abatement:
|
Employer provided a mobile scaffold / ladder system for safe access.
|